Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Intervalo de año de publicación
1.
Polymers (Basel) ; 16(9)2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38732757

RESUMEN

This study aimed to evaluate the effect of direct restorations using unidirectional glass fiber orientations and a short-fiber-reinforced composite (SFRC) on the fracture resistance of endodontically treated premolars with mesio-occluso-distal cavities. Ninety double-rooted premolars were selected. Fifteen teeth were left intact/as a control group. The endodontic treatment and cavity preparations of seventy-five teeth were performed and divided into five experimental groups: Resin composite (RC), modified transfixed technique + RC, circumferential technique + RC, cavity floor technique + RC, and SFRC + RC. All teeth were fractured under oblique static loading at a 30° angle using a universal testing machine. The fracture patterns were observed and classified. Data were analyzed with one-way analysis of variance, Pearson chi-square, and Tukey HSD post hoc tests (p = 0.05). The highest fracture strength values were obtained in intact teeth (599.336 N), followed by modified transfixed + RC treated teeth (496.58 N), SFRC + RC treated teeth (469.62 N), RC (443.51 N), circumferential + RC treated teeth (442.835 N), and cavity floor + RC treated teeth (404.623 N) (p < 0.05). There was no significant difference between the RC and the circumferential technique + RC (p > 0.05). Unrepairable fractures were observed at low rates (20%) in the modified transfixed + RC and SFRC + RC teeth, and at higher rates in RC (73.3%), cavity floor + RC (60%), and circumferential + RC (80%) teeth. The application of an SFRC or the modified transfixed technique yielded an improved fracture strength and the fracture pattern of ETPs being restored with a universal injectable composite.

2.
J Appl Biomater Funct Mater ; 22: 22808000241248886, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38678374

RESUMEN

OBJECTIVE: To evaluate the effect of COVID-19 preventive mouthwashes on the surface hardness, surface roughness (Ra), and color change (ΔE) of three different polymer-based composite CAD/CAM materials (Vita Enamic (ENA), Grandio Block (GB), Lava Ultimate (LU)). METHODS: A total of 100 rectangular-shaped specimens with dimensions of 2 mm × 7 mm × 12 mm were obtained by sectioning three different CAD/CAM blocks and randomly divided into five subgroups according to the 30 days of mouthwash immersion protocol as follows: Control: artificial saliva, PVP-I: 1% povidone-iodine, HP: 1.5% hydrogen peroxide, CPC: mouthwash containing 0.075% cetylpyridinium chloride, EO: mouthwash containing essential oils. Microhardness, Ra, and ΔE values were measured at baseline and after 30 days of immersion protocols. Data were analyzed using the Wald Chi-square, two-way ANOVA, and post hoc Tukey tests. RESULTS: The independent factors (materials and solutions) significantly influenced the microhardness and color (p < 0.001). Ra of the materials was not affected by any of the mouthwashes (p > 0.05). The microhardness and color of each material varied significantly after immersion in PvP-I and HP (p < 0.05). The highest percentage change in microhardness, Ra, and ΔE was found in LU immersed in PvP-I and HP mouthwashes, while the lowest change was found in ENA groups (p < 0.05). CONCLUSION: Within the limitations of this study, it was found that the surface hardness and color of tested polymer-based composite CAD/CAM materials are susceptible to degradation and change after 30 days of immersion in 1% PvP-I and 1.5% HP mouthwashes.


Asunto(s)
Antivirales , Cerámica , Dureza , Antisépticos Bucales , Propiedades de Superficie , Antisépticos Bucales/química , Antivirales/química , Color , Ensayo de Materiales , Cetilpiridinio/química , Resinas Compuestas/química , Humanos , Diseño Asistido por Computadora , COVID-19 , Povidona Yodada/química , Peróxido de Hidrógeno/química
3.
Odovtos (En línea) ; 25(2)ago. 2023.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1448738

RESUMEN

The aim of this study was to evaluate the whitening and abrasion effects of dentifrices containing different whitening agents on artificially stained and unstained enamel. 160 human dental enamel discs were distributed into four groups according to the type of dentifrices applied on them (n=40): Group I, non-whitening dentifrice (control group); Group II, dentifrice containing charcoal; Group III, dentifrice containing blue covarine; Group IV, dentifrice containing hydrogen peroxide. Half of the specimens in each group were immersed in coffee solution. Color measurements were evaluated from stained and unstained specimens before and after brushing by a spectrophotometer. The surface roughness of each unstained specimen was analyzed using a profilometer after the brushing and bleaching. The surface of one randomly selected specimen from each group was observed using a scanning electron microscope (SEM). Statistical analysis of the color change was performed using the Kruskal-Wallis test. The one-way ANOVA was used to evaluate surface roughness. Group III provided significantly higher recovery on ΔE00 values than other groups on the unstained enamel (p<0.05). Group IV showed significantly the highest ΔE00 values on stained enamel (p<0.05) and also Group IV showed the highest surface roughness values (p<0.05), SEM revealed a more irregular surface in groups III and IV. It can be stated that dentifrice containing blue covarine is both an effective and a safe way to provide whiter teeth with routine home tooth brushing.


El objetivo de este estudio fue evaluar los efectos de blanqueamiento y abrasión de los dentífricos que contienen diferentes agentes blanqueadores en el esmalte teñido y no teñido artificialmente. Se distribuyeron 160 discos de esmalte dental humano en cuatro grupos según el tipo de dentífrico aplicado sobre ellos (n=40): Grupo I, dentífrico no blanqueador (grupo control); Grupo II, dentífrico que contiene carbón vegetal; Grupo III, dentífrico que contiene azul; Grupo IV, dentífrico que contiene peróxido de hidrógeno. La mitad de los especímenes de cada grupo se sumergieron en una solución de café. Las mediciones de color se evaluaron a partir de especímenes teñidos y no teñidos antes y después del cepillado con un espectrofotómetro. La rugosidad de la superficie de cada muestra sin teñir se analizó utilizando un perfilómetro después del cepillado y del clareamiento. La superficie de un espécimen seleccionado al azar de cada grupo se observó utilizando un microscopio electrónico de barrido (MEB). El análisis estadístico del cambio de color se realizó utilizando la prueba de Kruskal-Wallis. Se utilizó el ANOVA para evaluar la rugosidad de la superficie. El grupo III proporcionó una recuperación significativamente mayor en los valores de ΔE00 que otros grupos en el esmalte no teñido (p<0,05). El Grupo IV mostró significativamente los valores más altos de ΔE00 en el esmalte teñido (p<0.05) y también el Grupo IV mostró los valores más altos de rugosidad superficial (p<0.05), el análisis en MEB reveló una superficie más irregular en los grupos III y IV. Se puede afirmar que el dentífrico que contiene azul es una forma efectiva y segura de proporcionar dientes más claros con el cepillado de rutina en el hogar.

4.
Aust Endod J ; 48(2): 258-265, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34259369

RESUMEN

This study aimed to evaluate dentinal tubule penetration of the root canal filling material using various techniques such as cold lateral compaction, new generation thermoplastic core carrier and continuous-wave obturation. The root canals of premolar teeth were instrumented, and the teeth were allocated randomly to three groups (n = 15/group). After the obturation with three different techniques, three sections of 2-mm thickness at 2, 5 and 8-mm from the apex were examined under a confocal laser scanning microscope. The data were analysed of variance with a significance level of P < 0.05. There was no significant difference between techniques when parameters were evaluated in total (penetration depth P = 0.418, penetration area P = 0.701). The mean value of the cold lateral compaction group for maximum penetration depth was obtained higher than continuous wave (P = 0.004), whilst there was no significant difference between the thermoplastic core carrier and the other groups.


Asunto(s)
Gutapercha , Materiales de Obturación del Conducto Radicular , Cavidad Pulpar , Resinas Epoxi , Microscopía Confocal , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular/métodos , Jeringas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...